Turbo-Elite
Laser atherectomy catheter
  • Philips Peripheral Laser Atherectomy Catheter Animation
  • The Turbo-Elite family of catheters can treat lesions both above and below the knee ablating material at the molecular level and modifying plaque for a more consistent outcome.¹⁻⁴
  • Turbo-Elite laser atherectomy catheter animation
  • With one of the largest size ranges of any atherectomy catheter, Turbo-Elite can fit into standard procedural practice working with the physician's preferred wire and introducer sheath.
  • Compatible in all types of morphologies from calcium to ISR* and is the only atherectomy device with zero contraindications.¹⁻⁴
  • Standard product photograph

Turbo-Elite

Laser atherectomy catheter
Turbo-Elite laser atherectomy catheter captures the power of ultraviolet light to provide a versatile and reliable tool for treating multiple lesion morphologies within PAD lesions. Utilizing laser's unique mechanism of action, Turbo-Elite is capable of powering through the most challenging restenoses and occlusions.

Clinical image gallery

  • Turbo-Elite: pre & post procedure
    Turbo-Elite: pre & post procedure
Features
Strong clinical support
Turbo-Elite has a proven record of safety and effectiveness with results that consistently demonstrate an ability to save limbs and treat lesions both above and below the knee.¹⁻⁴
Versatile performance
Turbo-Elite uniformly and reliably helps treat a variety of morphologies and locations with a single catheter.
Cost-effective solution
Through a single device that can both cross and debulk a lesion, Turbo-Elite provides you with clinical efficacy and reliability at a lower cost per case than other technologies.


Specifications
  • Model number 410-152 peripheral over-the-wire catheter
    Catheter diameter
    0.9 mm
    Vessel diameter
    ≥1.4 mm
    Max guidewire compatibility
    0.014”
    Sheath compatibility
    4F
    Max tip outer diameter
    0.038”
    Max shaft outer diameter
    0.047”
    Working length
    150 cm
    Fluence
    30-80 mJ/mm²
    Repetition
    25-80 Hz
  • Model number 414-151 peripheral over-the-wire catheter
    Catheter diameter
    1.4 mm
    Vessel diameter
    ≥2.1 mm
    Max guidewire compatibility
    0.014”
    Sheath compatibility
    5F
    Max tip outer diameter
    0.055”
    Max shaft outer diameter
    0.056”
    Working length
    150 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 417-152 peripheral over-the-wire catheter
    Catheter diameter
    1.7 mm
    Vessel diameter
    ≥2.6 mm
    Max guidewire compatibility
    0.018”
    Sheath compatibility
    5F
    Max tip outer diameter
    0.068”
    Max shaft outer diameter
    0.069”
    Working length
    150 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 420-006 peripheral over-the-wire catheter
    Catheter diameter
    2 mm
    Vessel diameter
    ≥3.0 mm
    Max guidewire compatibility
    0.018”
    Sheath compatibility
    6F
    Max tip outer diameter
    0.080”
    Max shaft outer diameter
    0.081”
    Working length
    150 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 423-001 peripheral over-the-wire catheter
    Catheter diameter
    2.3 mm
    Vessel diameter
    ≥3.5 mm
    Max guidewire compatibility
    0.018”
    Sheath compatibility
    7F
    Max tip outer diameter
    0.091”
    Max shaft outer diameter
    0.091”
    Working length
    120 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 425-011 peripheral over-the-wire catheter
    Catheter diameter
    2.5 mm
    Vessel diameter
    ≥3.8 mm
    Max guidewire compatibility
    0.018”
    Sheath compatibility
    8F
    Max tip outer diameter
    0.101”
    Max shaft outer diameter
    0.102”
    Working length
    110 cm
    Fluence
    30-45 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 423-135 peripheral over-the-wire catheter
    Catheter diameter
    2.3 mm
    Vessel diameter
    ≥3.5 mm
    Max guidewire compatibility
    0.035”
    Sheath compatibility
    7F
    Max tip outer diameter
    0.091”
    Max shaft outer diameter
    0.091”
    Working length
    125 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 425-135 peripheral over-the-wire catheter
    Catheter diameter
    2.5 mm
    Vessel diameter
    ≥3.8 mm
    Max guidewire compatibility
    0.035”
    Sheath compatibility
    8F
    Max tip outer diameter
    0.101”
    Max shaft outer diameter
    0.102”
    Working length
    112 cm
    Fluence
    30-60mJ/mm²
    Repetition rate
    25-80Hz
  • Model number 410-154 peripheral rapid exchange catheter
    Catheter diameter
    0.9 mm
    Vessel diameter
    ≥1.4 mm
    Max guidewire compatibility
    0.014”
    Sheath compatibility
    4F
    Max tip outer diameter
    0.038”
    Max shaft outer diameter
    0.049”
    Working length
    150 cm
    Fluence
    30-80 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 414-159 peripheral rapid exchange catheter
    Catheter diameter
    1.4 mm
    Vessel diameter
    ≥2.1 mm
    Max guidewire compatibility
    0.014”
    Sheath compatibility
    5F
    Max tip outer diameter
    0.057”
    Max shaft outer diameter
    0.062”
    Working length
    150 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 417-156 peripheral rapid exchange catheter
    Catheter diameter
    1.7 mm
    Vessel diameter
    ≥2.6 mm
    Max guidewire compatibility
    0.014”
    Sheath compatibility
    6F
    Max tip outer diameter
    0.069” in
    Max shaft outer diameter
    0.072”
    Working length
    150 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 420-159 peripheral rapid exchange catheter
    Catheter diameter
    2 mm
    Vessel diameter
    ≥3.0 mm
    Max guidewire compatibility
    0.014”
    Sheath compatibility
    7F
    Max tip outer diameter
    0.080”
    Max shaft outer diameter
    0.084”
    Working length
    150 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz


Documentation

Turbo-Elite Laser Atherectomy Catheter Brochure
PDF|1.93 MB

Related products

  • CVX-300 Excimer laser system
    The only PMA approved excimer laser system and disposable catheters for the treatment of coronary arterial disease. CVX-300 is also indicated for use in the treatment of peripheral arterial disease. Photoablation is the use of light to break down, vaporize and remove matter. The CVX-300 excimer laser system facilitates photoablation via a variety of Philips laser catheters to remove binding arterial plaques.
  • Philips Laser System — Nexcimer Laser system for coronary and peripheral atherectomy and lead management
    Philips Laser System —Nexcimer— photoablates a wide spectrum of morphologies. Philips laser catheters are indicated in many vessel types and is the only laser system available for lead removal. Powered by a common 100-240V electrical outlet, the system warms up in less than 30 seconds for an easy and fast set-up.
  • Phoenix Atherectomy System Rotational atherectomy system
    The Phoenix atherectomy system combines the benefits of existing atherectomy systems to deliver a unique atherectomy option to help physicians tailor the treatment approach for each patient.¹ It cuts, captures, and clears diseased tissue with one insertion. Phoenix treats a broad range of tissue types, from soft plaque to calcified arteries, and can be used for lesions above and below the knee.²,³
Disclaimer
1. Dippel et al. Excimer laser recanalization of femoropopliteal lesions and 1-year patency: results of the CELLO registry. J Endovasc Ther. 2009 Dec;16(6):665-75.
2. Zeller et al. J Endovasc Ther. Photoablation using the turbo-booster and excimer laser for in-stent restenosis treatment: twelve-month results from the PATENT study. J Endovasc Ther. 2014 Feb;21(1):52-60
3. Dippel et al. Randomized controlled study of excimer laser atherectomy for treatment of femoropopliteal in-stent restenosis: initial results from the EXCITE ISR trial (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis). JACC Cardiovasc Interv. 2015 Jan;8(1 Pt A):92-101
4. Laird et al.  Limb Salvage Following Laser-Assisted Angioplasty for Critical Limb Ischemia: Results of the LACI Multi­center Trial. J Endovasc Ther. 2006 Feb;13(1):1-11
*When used with Turbo-Tandem and PTA
**Images courtesy of Dr. Devendra Amin
Product availability is subject to country regulatory clearance. Please contact your local sales representative to check the availability in your country.